You can rest assured to buy Lixin SZW26-20/D202.2 Isolating for Water Pump from our factory. The LW26 series rotary switches, such as the 3 Position On-off-On Rotary Cam Switch, are designed to be utilized in electrical systems operating at 50Hz AC frequency. They can handle operational voltages of up to 440V AC and DC voltages up to 240V, with a rated current capacity of up to 315A. These switches provide dependable control for occasional manual circuit connections or disconnections, making them adaptable for a wide range of applications. Moreover, they enable direct control of three-phase asynchronous motors, fulfilling both primary command control and circuit measurement requirements.
As the professional manufacturer, we would like to provide you Lixin SZW26-20/D202.2 Isolating for Water Pump. Tailored for applications requiring speed adjustment, the 3 Position On-off-On Rotary Cam Switch provides enhanced operational versatility. Within the LW26 series, these switches serve multiple functions, functioning as circuit control switches, testing equipment switches, motor control switches, and primary command control switches, including applications in welding machines.
Certified to adhere to standards such as GB/T 14048.3, GB/T 14048.5, and EN60947-5-1, the LW26 series ensures compliance with industry regulations. Available in a range of specifications from 10A to 315A, these switches feature compact designs, meticulous material selection, and robust insulation properties. Their flexible switching operations, combined with safety features like finger protection in models such as LW26-10, LW26-20, LW26-25, and LW26-32, ensure dependable performance in diverse environments.
Presenting an innovative solution, the LW26 series offers an ideal upgrade option, capable of replacing older switch models such as LW2, LW5, LW6, LW8, LW12, HZ5, HZ10, and HZ12, as well as switching switches in imported equipment.
Controls way |
trait designation |
Actuator position |
|||
Self-replicating type |
A |
0°30° |
0-45° |
0°-60° |
|
B |
30°-0°30° |
45°0°-45° |
60°0°-60° |
||
X |
60-30=0°30-60° |
||||
Locating type |
C |
0°30° |
0°45° |
0°60° |
|
D |
30°0°30° |
45°0°45° |
60°0°60° |
||
E |
30°0°30°60° |
45°0°45°90° |
60°0*60*120° |
||
F |
60°30°0°30°60° |
90°45°0°45°90° |
60°0°60°120°180° |
||
G |
60°30°0°30°60°90° |
90°45°0°45°90°135° |
120°60°0°60°120°180° |
||
H |
90°60°30°0°30°60°90° |
135°90°45°0°45°90°135° |
|||
90°60°30°0°30°60°90°120° |
135°90°45°0°45°90°135°180° |
||||
J |
120°90°60°30°0°30°60°90°120° |
||||
K |
120°90°60°30°0°30°60°90°120°150° |
||||
L |
150°120°90°60°30°0°30°60°90°120°150° |
||||
M |
150°120°90°60°30°0°30°60°90°120°150°180° |
||||
N |
45° 45° |
30°30° |
|||
P |
90°0°90 |
||||
T |
0*90° |
||||
V |
90°0° |
||||
R |
270°0°90°180° |
||||
orientation Self-replicating type |
Q |
30°0°-30° |
45-0°45° |
||
S |
30°-0°60° |
90°0°-45 |
|||
W |
90-45°0°45-90° |
||||
Z |
120°-90°0⁰-30° |
135°-90°0⁶-45° |
Type specification |
LW26-10 LW26-10G LW26-10X |
LW26-20 LW26-20X LW26-20C |
LW26-25 |
LW26-32 LW26-32F |
LW26-40 LW26-40F |
LW26-63 LW26-63F |
LW26-125 |
LW26-160 |
LW26-250 |
LW26-315 |
Ui V |
660/690 |
660 |
660 |
660 |
660 |
660 |
660 |
660 |
660 |
660 |
Ith A |
10 |
20 |
25 |
32 |
40 |
63 |
125 |
160 |
250 |
315 |
Ue V |
240440 |
24110240440 |
24110240440 |
240440 |
240440 |
240440 |
240440 |
240 440 |
240440 |
240440 |
le |
||||||||||
AC-21A AC-22A A |
1010 |
20 20 |
25 25 |
32 32 |
63 63 |
100 100 |
150 150 |
200200 |
315 315 |
|
AC-23A A |
7.57.5 |
15 15 |
22 22 |
30 30 |
37 37 |
57 57 |
90 90 |
135 135 |
265 265 |
|
AC-3 A |
5.55.5 |
11 11 |
15 15 |
22 22 |
30 30 |
36 36 |
75 75 |
95 95 |
110 110 |
|
AC-4 A |
1.751.75 |
3.5 3.5 |
6.5 6.5 |
11 11 |
15 15 |
30 30 |
55 55 |
95 95 |
||
AC-15 A |
2.51.5 |
5 4 |
8 5 |
14 6 |
||||||
DC-13 A |
12 0.40.4 |
20 0.5 0.5 |
||||||||
Rated control power P |
||||||||||
AC-23A KW |
1.8 3 |
3.7/2.5 7.5/3.7 |
5.5/311/5.5 |
75/415/75 |
185/918.5/9 |
15/1030/18.5 |
30/1545/22 |
37/2275/37 |
75/37132/55 |
|
AC-2 KW |
2.53.7 |
4 7.5 |
5.5 11 |
75 15 |
185 30 |
30 45 |
37 55 |
55 95 |
||
AC-3 KW |
1.52.2 |
3/22 5.5/3 |
4/3 7.5/3.7 |
55/411/5.5 |
15/7.515/7.5 |
11/618.5/11 |
15/7.530/13 |
22/1137/18.5 |
37/2255/30 |
|
AC-4 KW |
0.370.55 |
0.55/0.751.5/1.5 |
1.5/1.13/2.2 |
27/1.555/3 |
55/2475/4 |
6/312/5.5 |
10/415/7.5 |
15/7.525/11 |
1. The ambient air temperature must remain within the range of -25°C to +40°C, with a 24-hour average not exceeding 25°C.
2. The lower limit of the ambient air temperature should not drop below -25°C.
3. Installation locations should not exceed an altitude of 2000m above sea level.
4. At maximum temperature conditions of +40°C, the relative humidity of the air should not exceed 50%. Higher relative humidity levels may be permissible at lower temperatures, such as reaching 90% at 20°C. Special precautions must be taken to mitigate condensation resulting from temperature fluctuations.
1. The switch is installed in an environment with pollution level 3 conditions.
2. Installation should be carried out according to the instructions provided by our factory.
1 Divided by use
(1) Switch for main circuit conversion;
(2) Transfer switch for direct control of the motor; (3) Transfer switch for master control and measurement.
2 According to the operation mode
(1) Positioning type;
(2) self-replicating type;
(3) Positioning self-replicating type.
3 According to the contact system
(1) The positioning type switch has 1 to 12 sections (only 8 sections for 63A and above switches);
(2) The self-restoring type transfer switch has 1 to 3 sections (LW26-20; Verses 1 to 8)
(3) The transfer switch for direct control of the motor mainly has 1 to 6 sections.
Lixin 3 Position On-off-On Rotary Cam Switch Overall dimensions and mounting dimensions: